Gas stove steam collector (drum) can not enter the water, what is the reason?
TIME:2017-1-21 11:49:02 | VIEW:
In operation, sometimes the individual gas furnace will not produce water into the drum into the phenomenon, then although the other furnace is in the normal water, the following reasons:
1. Water automatic control valve failure, in a closed state.
2. Manual adjustment of the water pipe plug phenomenon.
3. The steam inside the steam drum is not timely used or released, resulting in increased pressure, while the water pressure is low, the vapor pressure is greater than
Water pressure, the water can not enter the water.
4. In the front of the inlet manifold a large number of water into the furnace, resulting in the end of the water inlet tube into the boiler can not water.