Gas burner in the ignition operation of the note
TIME:2017-4-1 14:57:31 | VIEW:
1, the gas furnace before the fire check the water tank is filled (water level ≥ 2/3 water tank level), the tank connected to the gas furnace feed valve must be opened.
2, to the gas furnace coal, cover the lid and fill the lid filled with water (water seal).
3, open the valve, and slightly open the valve.
4, to be ready after all the ignition operation, ignite the source of liquefied gas and from the ignition hole into the kiln, while opening the combustion fan and gas furnace fan, and by adjusting the combustion air flow to the burner stable combustion, if the flame off , Must continue to ignite until ignited.
5, burner flame stability, you can open the cycle fan.

 